1
Fork 0
mirror of https://github.com/RGBCube/superfreq synced 2025-07-27 17:07:44 +00:00

engine: simplify AC power status determination

This commit is contained in:
NotAShelf 2025-05-18 03:58:19 +03:00
parent 8a92c124b1
commit 5f1d2c9748
No known key found for this signature in database
GPG key ID: 29D95B64378DB4BF
2 changed files with 10 additions and 11 deletions

View file

@ -222,9 +222,7 @@ impl From<ProfileConfigToml> for ProfileConfig {
min_freq_mhz: toml_config.min_freq_mhz,
max_freq_mhz: toml_config.max_freq_mhz,
platform_profile: toml_config.platform_profile,
turbo_auto_settings: toml_config
.turbo_auto_settings
.unwrap_or_default(),
turbo_auto_settings: toml_config.turbo_auto_settings.unwrap_or_default(),
enable_auto_turbo: toml_config.enable_auto_turbo,
battery_charge_thresholds: toml_config.battery_charge_thresholds,
}

View file

@ -202,13 +202,7 @@ pub fn determine_and_apply_settings(
}
}
if let Some(turbo_setting) = selected_profile_config.turbo {
info!("Setting turbo to '{turbo_setting:?}'");
match turbo_setting {
TurboSetting::Auto => {
if selected_profile_config.enable_auto_turbo {
debug!("Managing turbo in auto mode based on system conditions");
// Determine AC status and pass it to manage_auto_turbo
// Determine AC/Battery status once for the entire function
let on_ac_power = if report.batteries.is_empty() {
// No batteries means desktop/server, always on AC
true
@ -216,6 +210,13 @@ pub fn determine_and_apply_settings(
// Check if any battery reports AC connected
report.batteries.iter().any(|b| b.ac_connected)
};
if let Some(turbo_setting) = selected_profile_config.turbo {
info!("Setting turbo to '{turbo_setting:?}'");
match turbo_setting {
TurboSetting::Auto => {
if selected_profile_config.enable_auto_turbo {
debug!("Managing turbo in auto mode based on system conditions");
manage_auto_turbo(report, selected_profile_config, on_ac_power)?;
} else {
debug!(