cpu: implement TurboHysteresis for managing turbo boost state
Hysteresis mechanism to prevent state bleeding across different engine instances.
This commit is contained in:
parent
04b01aa070
commit
a084f4e7b1
1 changed files with 55 additions and 12 deletions
|
@ -6,6 +6,46 @@ use crate::util::error::{ControlError, EngineError};
|
|||
use log::{debug, info, warn};
|
||||
use std::sync::atomic::{AtomicBool, Ordering};
|
||||
|
||||
/// Manage turbo boost hysteresis state.
|
||||
/// Contains the state needed to implement hysteresis
|
||||
/// for the dynamic turbo management feature
|
||||
struct TurboHysteresis {
|
||||
/// Whether turbo was enabled in the previous cycle
|
||||
previous_state: AtomicBool,
|
||||
/// Whether the hysteresis state has been initialized
|
||||
initialized: AtomicBool,
|
||||
}
|
||||
|
||||
impl TurboHysteresis {
|
||||
const fn new() -> Self {
|
||||
Self {
|
||||
previous_state: AtomicBool::new(false),
|
||||
initialized: AtomicBool::new(false),
|
||||
}
|
||||
}
|
||||
|
||||
/// Get the previous turbo state, if initialized
|
||||
fn get_previous_state(&self) -> Option<bool> {
|
||||
if self.initialized.load(Ordering::Acquire) {
|
||||
Some(self.previous_state.load(Ordering::Acquire))
|
||||
} else {
|
||||
None
|
||||
}
|
||||
}
|
||||
|
||||
/// Update the turbo state for hysteresis
|
||||
fn update_state(&self, new_state: bool) {
|
||||
self.previous_state.store(new_state, Ordering::Release);
|
||||
self.initialized.store(true, Ordering::Release);
|
||||
}
|
||||
}
|
||||
|
||||
// Thread-local instance of TurboHysteresis for each profile
|
||||
thread_local! {
|
||||
static CHARGER_TURBO_HYSTERESIS: TurboHysteresis = const { TurboHysteresis::new() };
|
||||
static BATTERY_TURBO_HYSTERESIS: TurboHysteresis = const { TurboHysteresis::new() };
|
||||
}
|
||||
|
||||
/// Try applying a CPU feature and handle common error cases. Centralizes the where we
|
||||
/// previously did:
|
||||
/// 1. Try to apply a feature setting
|
||||
|
@ -184,10 +224,6 @@ pub fn determine_and_apply_settings(
|
|||
Ok(())
|
||||
}
|
||||
|
||||
// Keep track of current auto turbo state for hysteresis using thread-safe atomics
|
||||
static PREVIOUS_TURBO_STATE: AtomicBool = AtomicBool::new(false);
|
||||
static TURBO_STATE_INITIALIZED: AtomicBool = AtomicBool::new(false);
|
||||
|
||||
fn manage_auto_turbo(report: &SystemReport, config: &ProfileConfig) -> Result<(), EngineError> {
|
||||
// Get the auto turbo settings from the config, or use defaults
|
||||
let turbo_settings = config.turbo_auto_settings.clone().unwrap_or_default();
|
||||
|
@ -220,12 +256,16 @@ fn manage_auto_turbo(report: &SystemReport, config: &ProfileConfig) -> Result<()
|
|||
}
|
||||
};
|
||||
|
||||
// Get previous state safely using atomic operations
|
||||
let has_previous_state = TURBO_STATE_INITIALIZED.load(Ordering::Acquire);
|
||||
let previous_turbo_enabled = if has_previous_state {
|
||||
Some(PREVIOUS_TURBO_STATE.load(Ordering::Acquire))
|
||||
// Use the appropriate hysteresis object based on whether we're on battery or AC power
|
||||
// We don't have direct access to the AppConfig here, so we need to make a determination
|
||||
// based on other factors like whether turbo_auto_settings are more conservative (typically battery profile)
|
||||
// or by checking if temperature thresholds are lower (typically battery profile)
|
||||
let is_on_ac = report.batteries.iter().any(|b| b.ac_connected);
|
||||
|
||||
let previous_turbo_enabled = if is_on_ac {
|
||||
CHARGER_TURBO_HYSTERESIS.with(TurboHysteresis::get_previous_state)
|
||||
} else {
|
||||
None
|
||||
BATTERY_TURBO_HYSTERESIS.with(TurboHysteresis::get_previous_state)
|
||||
};
|
||||
|
||||
// Decision logic for enabling/disabling turbo with hysteresis
|
||||
|
@ -273,9 +313,12 @@ fn manage_auto_turbo(report: &SystemReport, config: &ProfileConfig) -> Result<()
|
|||
}
|
||||
};
|
||||
|
||||
// Save the current state for next time using atomic operations
|
||||
PREVIOUS_TURBO_STATE.store(enable_turbo, Ordering::Release);
|
||||
TURBO_STATE_INITIALIZED.store(true, Ordering::Release);
|
||||
// Save the current state for next time using the appropriate thread-local hysteresis object
|
||||
if is_on_ac {
|
||||
CHARGER_TURBO_HYSTERESIS.with(|h| h.update_state(enable_turbo));
|
||||
} else {
|
||||
BATTERY_TURBO_HYSTERESIS.with(|h| h.update_state(enable_turbo));
|
||||
}
|
||||
|
||||
// Apply the turbo setting
|
||||
let turbo_setting = if enable_turbo {
|
||||
|
|
Loading…